Duque, Alaine et al. published their research in Talanta in 2022 |CAS: 6197-30-4

The Article related to deep eutectic solvent ferrofluid uv filter dispersive liquid microextraction, deep eutectic solvent, ferrofluid, liquid chromatography-tandem mass spectrometry, stir bar dispersive liquid microextraction, uv filters, water samples and other aspects.Recommanded Product: 2-Ethylhexyl 2-cyano-3,3-diphenylacrylate

On June 1, 2022, Duque, Alaine; Grau, Jose; Benede, Juan L.; Alonso, Rosa M.; Campanero, Miguel A.; Chisvert, Alberto published an article.Recommanded Product: 2-Ethylhexyl 2-cyano-3,3-diphenylacrylate The title of the article was Low toxicity deep eutectic solvent-based ferrofluid for the determination of UV filters in environmental waters by stir bar dispersive liquid microextraction. And the article contained the following:

In this work, a low toxicity deep eutectic solvent-based ferrofluid is presented for the first time as magnetic fluid to be used as an efficient solvent in liquid-based microextraction techniques. This ferrofluid is made of a hydrophobic deep eutectic solvent, composed by menthol and thymol in a 1:5 molar ratio as carrier solvent, and oleic acid-coated cobalt ferrite (CoFe2O4@oleic acid) magnetic nanoparticles. This material was characterized via magnetism measurement, SEM, IR spectroscopy and d. measurement. The determination of UV filters in environmental water samples was selected as model anal. application to test the extraction performance of this new ferrofluid by employing stir bar dispersive liquid microextraction, prior to liquid chromatog.-tandem mass spectrometry anal. The response surface methodol. was used as a multivariate optimization method for extraction step. Under the optimized conditions, good anal. features were obtained, such as low limits of detection between 7 and 83 ng L-1, good repeatability (relative standard deviations, RSD (%) below 15%), enrichment factors between 46 and 101 and relative recoveries between 80 and 117%, proving the good extraction capability of this ferrofluid. Finally, the method was successfully applied to three environmental waters (beach and river waters), finding trace amounts of the target UV filters. The presented low toxicity deep eutectic solvent-based ferrofluid results to be a good alternative to conventional solvents used in liquid-phase microextraction techniques. The experimental process involved the reaction of 2-Ethylhexyl 2-cyano-3,3-diphenylacrylate(cas: 6197-30-4).Recommanded Product: 2-Ethylhexyl 2-cyano-3,3-diphenylacrylate

The Article related to deep eutectic solvent ferrofluid uv filter dispersive liquid microextraction, deep eutectic solvent, ferrofluid, liquid chromatography-tandem mass spectrometry, stir bar dispersive liquid microextraction, uv filters, water samples and other aspects.Recommanded Product: 2-Ethylhexyl 2-cyano-3,3-diphenylacrylate

Referemce:
Ester – Wikipedia,
Ester – an overview | ScienceDirect Topics